Skip to content

Configuration changes

This document covers recent software changes to the config file that are not backwards compatible. It is a good idea to review this document when upgrading the Klipper software.

All dates in this document are approximate.

Changes

20210720: A controller_fan section now monitors all stepper motors by default (not just the kinematic stepper motors). If the previous behavior is desired, see the stepper config option in the config reference.

20210703: A samd_sercom config section must now specify the sercom bus it is configuring via the sercom option.

20210612: The pid_integral_max config option in heater and temperature_fan sections is deprecated. The option will be removed in the near future.

20210503: The gcode_macro default_parameter_<name> config option is deprecated. Use the params pseudo-variable to access macro parameters. Other methods for accessing macro parameters will be removed in the near future. See the Command Templates document for examples.

20210430: The SET_VELOCITY_LIMIT (and M204) command may now set a velocity, acceleration, and square_corner_velocity larger than the specified values in the config file.

20210325: Support for the pin_map config option is deprecated. Use the sample-aliases.cfg file to translate to the actual micro-controller pin names. The pin_map config option will be removed in the near future.

20210313: Klipper's support for micro-controllers that communicate with CAN bus has changed. If using CAN bus then all micro-controllers must be reflashed and the Klipper configuration must be updated.

20210310: The TMC2660 default for driver_SFILT has been changed from 1 to 0.

20210227: TMC stepper motor drivers in UART or SPI mode are now queried once per second whenever they are enabled - if the driver can not be contacted or if the driver reports an error, then Klipper will transition to a shutdown state.

20210219: The rpi_temperature module has been renamed to temperature_host. Replace any occurrences of sensor_type: rpi_temperature with sensor_type: temperature_host. The path to the temperature file may be specified in the sensor_path config variable. The rpi_temperature name is deprecated and will be removed in the near future.

20210201: The TEST_RESONANCES command will now disable input shaping if it was previously enabled (and re-enable it after the test). In order to override this behavior and keep the input shaping enabled, one can pass an additional parameter INPUT_SHAPING=1 to the command.

20210201: The ACCELEROMETER_MEASURE command will now append the name of the accelerometer chip to the output file name if the chip was given a name in the corresponding adxl345 section of the printer.cfg.

20201222: The step_distance setting in the stepper config sections is deprecated. It is advised to update the config to use the rotation_distance setting. Support for step_distance will be removed in the near future.

20201218: The endstop_phase setting in the endstop_phase module has been replaced with trigger_phase. If using the endstop phases module then it will be necessary to convert to rotation_distance and recalibrate any endstop phases by running the ENDSTOP_PHASE_CALIBRATE command.

20201218: Rotary delta and polar printers must now specify a gear_ratio for their rotary steppers, and they may no longer specify a step_distance parameter. See the config reference for the format of the new gear_ratio paramter.

20201213: It is not valid to specify a Z "position_endstop" when using "probe:z_virtual_endstop". An error will now be raised if a Z "position_endstop" is specified with "probe:z_virtual_endstop". Remove the Z "position_endstop" definition to fix the error.

20201120: The [board_pins] config section now specifies the mcu name in an explicit mcu: parameter. If using board_pins for a secondary mcu, then the config must be updated to specify that name. See the config reference for further details.

20201112: The time reported by print_stats.print_duration has changed. The duration prior to the first detected extrusion is now excluded.

20201029: The neopixel color_order_GRB config option has been removed. If necessary, update the config to set the new color_order option to RGB, GRB, RGBW, or GRBW.

20201029: The serial option in the mcu config section no longer defaults to /dev/ttyS0. In the rare situation where /dev/ttyS0 is the desired serial port, it must be specified explicitly.

20201020: Klipper v0.9.0 released.

20200902: The RTD resistance-to-temperature calculation for MAX31865 converters has been corrected to not read low. If you are using such a device, you should recalibrate your print temperature and PID settings.

20200816: The gcode macro printer.gcode object has been renamed to printer.gcode_move. Several undocumented variables in printer.toolhead and printer.gcode have been removed. See docs/Command_Templates.md for a list of available template variables.

20200816: The gcode macro "action_" system has changed. Replace any calls to printer.gcode.action_emergency_stop() with action_emergency_stop(), printer.gcode.action_respond_info() with action_respond_info(), and printer.gcode.action_respond_error() with action_raise_error().

20200809: The menu system has been rewritten. If the menu has been customized then it will be necessary to update to the new configuration. See config/example-menu.cfg for configuration details and see klippy/extras/display/menu.cfg for examples.

20200731: The behavior of the progress attribute reported by the virtual_sdcard printer object has changed. Progress is no longer reset to 0 when a print is paused. It will now always report progress based on the internal file position, or 0 if no file is currently loaded.

20200725: The servo enable config parameter and the SET_SERVO ENABLE parameter have been removed. Update any macros to use SET_SERVO SERVO=my_servo WIDTH=0 to disable a servo.

20200608: The LCD display support has changed the name of some internal "glyphs". If a custom display layout was implemented it may be necessary to update to the latest glyph names (see klippy/extras/display/display.cfg for a list of available glyphs).

20200606: The pin names on linux mcu have changed. Pins now have names of the form gpiochip<chipid>/gpio<gpio>. For gpiochip0 you can also use a short gpio<gpio>. For example, what was previously referred to as P20 now becomes gpio20 or gpiochip0/gpio20.

20200603: The default 16x4 LCD layout will no longer show the estimated time remaining in a print. (Only the elapsed time will be shown.) If the old behavior is desired one can customize the menu display with that information (see the description of display_data in config/example-extras.cfg for details).

20200531: The default USB vendor/product id is now 0x1d50/0x614e. These new ids are reserved for Klipper (thanks to the openmoko project). This change should not require any config changes, but the new ids may appear in system logs.

20200524: The default value for the tmc5160 pwm_freq field is now zero (instead of one).

20200425: The gcode_macro command template variable printer.heater was renamed to printer.heaters.

20200313: The default lcd layout for multi-extruder printers with a 16x4 screen has changed. The single extruder screen layout is now the default and it will show the currently active extruder. To use the previous display layout set "display_group: _multiextruder_16x4" in the [display] section of the printer.cfg file.

20200308: The default __test menu item was removed. If the config file has a custom menu then be sure to remove all references to this __test menu item.

20200308: The menu "deck" and "card" options were removed. To customize the layout of an lcd screen use the new display_data config sections (see config/example-extras.cfg for the details).

20200109: The bed_mesh module now references the probe's location in for the mesh configuration. As such, some configuration options have been renamed to more accurately reflect their intended functionality. For rectangular beds, min_point and max_point have been renamed to mesh_min and mesh_max respectively. For round beds, bed_radius has been renamed to mesh_radius. A new mesh_origin option has also been added for round beds. Note that these changes are also incompatible with previously saved mesh profiles. If an incompatible profile is detected it will be ignored and scheduled for removal. The removal process can be completed by issuing the SAVE_CONFIG command. The user will need to re-calibrate each profile.

20191218: The display config section no longer supports "lcd_type: st7567". Use the "uc1701" display type instead - set "lcd_type: uc1701" and change the "rs_pin: some_pin" to "rst_pin: some_pin". It may also be necessary to add a "contrast: 60" config setting.

20191210: The builtin T0, T1, T2, ... commands have been removed. The extruder activate_gcode and deactivate_gcode config options have been removed. If these commands (and scripts) are needed then define individual [gcode_macro T0] style macros that call the ACTIVATE_EXTRUDER command. See the config/sample-idex.cfg and sample-multi-extruder.cfg files for examples.

20191210: Support for the M206 command has been removed. Replace with calls to SET_GCODE_OFFSET. If support for M206 is needed, add a [gcode_macro M206] config section that calls SET_GCODE_OFFSET. (For example "SET_GCODE_OFFSET Z=-{params.Z}".)

20191202: Support for the undocumented "S" parameter of the "G4" command has been removed. Replace any occurrences of S with the standard "P" parameter (the delay specified in milliseconds).

20191126: The USB names have changed on micro-controllers with native USB support. They now use a unique chip id by default (where available). If an "mcu" config section uses a "serial" setting that starts with "/dev/serial/by-id/" then it may be necessary to update the config. Run "ls /dev/serial/by-id/*" in an ssh terminal to determine the new id.

20191121: The pressure_advance_lookahead_time parameter has been removed. See example.cfg for alternate configuration settings.

20191112: The tmc stepper driver virtual enable capability is now automatically enabled if the stepper does not have a dedicated stepper enable pin. Remove references to tmcXXXX:virtual_enable from the config. The ability to control multiple pins in the stepper enable_pin config has been removed. If multiple pins are needed then use a multi_pin config section.

20191107: The primary extruder config section must be specified as "extruder" and may no longer be specified as "extruder0". Gcode command templates that query the extruder status are now accessed via "{printer.extruder}".

20191021: Klipper v0.8.0 released

20191003: The move_to_previous option in [safe_z_homing] now defaults to False. (It was effectively False prior to 20190918.)

20190918: The zhop option in [safe_z_homing] is always re-applied after Z axis homing completed. This might need users to update custom scripts based on this module.

20190806: The SET_NEOPIXEL command has been renamed to SET_LED.

20190726: The mcp4728 digital-to-analog code has changed. The default i2c_address is now 0x60 and the voltage reference is now relative to the mcp4728's internal 2.048 volt reference.

20190710: The z_hop option was removed from the [firmware_retract] config section. The z_hop support was incomplete and could cause incorrect behavior with several common slicers.

20190710: The optional parameters of the PROBE_ACCURACY command have changed. It may be necessary to update any macros or scripts that use that command.

20190628: All configuration options have been removed from the [skew_correction] section. Configuration for skew_correction is now done via the SET_SKEW gcode. See skew_correction.md for recommended usage.

20190607: The "variable_X" parameters of gcode_macro (along with the VALUE parameter of SET_GCODE_VARIABLE) are now parsed as Python literals. If a value needs to be assigned a string then wrap the value in quotes so that it is evaluated as a string.

20190606: The "samples", "samples_result", and "sample_retract_dist" config options have been moved to the "probe" config section. These options are no longer supported in the "delta_calibrate", "bed_tilt", "bed_mesh", "screws_tilt_adjust", "z_tilt", or "quad_gantry_level" config sections.

20190528: The magic "status" variable in gcode_macro template evaluation has been renamed to "printer".

20190520: The SET_GCODE_OFFSET command has changed; update any g-code macros accordingly. The command will no longer apply the requested offset to the next G1 command. The old behavior may be approximated by using the new "MOVE=1" parameter.

20190404: The Python host software packages were updated. Users will need to rerun the ~/klipper/scripts/install-octopi.sh script (or otherwise upgrade the python dependencies if not using a standard OctoPi installation).

20190404: The i2c_bus and spi_bus parameters (in various config sections) now take a bus name instead of a number.

20190404: The sx1509 config parameters have changed. The 'address' parameter is now 'i2c_address' and it must be specified as a decimal number. Where 0x3E was previously used, specify 62.

20190328: The min_speed value in [temperature_fan] config will now be respected and the fan will always run at this speed or higher in PID mode.

20190322: The default value for "driver_HEND" in [tmc2660] config sections was changed from 6 to 3. The "driver_VSENSE" field was removed (it is now automatically calculated from run_current).

20190310: The [controller_fan] config section now always takes a name (such as [controller_fan my_controller_fan]).

20190308: The "driver_BLANK_TIME_SELECT" field in [tmc2130] and [tmc2208] config sections has been renamed to "driver_TBL".

20190308: The [tmc2660] config section has changed. A new sense_resistor config parameter must now be provided. The meaning of several of the driver_XXX parameters has changed.

20190228: Users of SPI or I2C on SAMD21 boards must now specify the bus pins via a [samd_sercom] config section.

20190224: The bed_shape option has been removed from bed_mesh. The radius option has been renamed to bed_radius. Users with round beds should supply the bed_radius and round_probe_count options.

20190107: The i2c_address parameter in the mcp4451 config section changed. This is a common setting on Smoothieboards. The new value is half the old value (88 should be changed to 44, and 90 should be changed to 45).

20181220: Klipper v0.7.0 released

Back to top